Troubleshooting
This is the triage guide. Match your symptom, apply the fix, then
re-check radioactive_ralph doctor to confirm.
Stale heartbeat
Symptom
The client hangs, or reports the supervisor as up when it's actually dead.
What it means
The supervisor process crashed without cleaning its socket and heartbeat file. The socket / named pipe still exists on disk, so a dial can succeed at the OS level even though nothing answers — a fresh supervisor startup detects this (dead PID behind the lockfile) and reclaims automatically; a stuck client predates that reclaim.
Fix
# 1. Stop the supervisor if it's somehow still alive.
pgrep -f "radioactive_ralph --supervisor" && kill <pid>
# 2. Remove the stale socket + heartbeat file by hand if needed.
rm -f "$HOME/Library/Application Support/radioactive-ralph/service.sock"
rm -f "$HOME/Library/Application Support/radioactive-ralph/service.sock.alive"
# 3. Restart the supervisor.
radioactive_ralph --supervisor # or the OS service manager restartVerify by running the client:
radioactive_ralphDead socket or pipe
Symptom (Unix)
error: ipc: dial /path/to/service.sock: connection refusedSymptom (Windows)
error: ipc: dial \\.\pipe\radioactive_ralph-<token>-service: pipe does not existFix
Either the supervisor never started or the OS cleaned the endpoint.
# 1. Is the supervisor actually running?
pgrep -f "radioactive_ralph --supervisor" # Unix
Get-Process | Where-Object { $_.ProcessName -like "*radioactive*" } # Windows
# 2a. If yes: stop it, remove the stale endpoint, restart.
kill <pid>
rm -f "<state-root>/service.sock" # Unix; Windows pipes clear on reboot
radioactive_ralph --supervisor
# 2b. If no: just start it.
radioactive_ralph --supervisorOn Windows, named pipes are killed when the foreground supervisor exits and
at reboot. That's normal — run radioactive_ralph --supervisor again as the
same interactive user for the limited control plane. Native provider workers
remain unsupported and SCM start is intentionally disabled in v0.22; use WSL2
for functional execution.
Provider CLI missing or unauthenticated
Symptom
doctor: [FAIL] claude — claude binary not on PATHFix
See Provider auth for the full flow. The short version:
# Install if missing
curl -fsSL https://anthropic.com/install.sh | sh
# Authenticate
claude
# (first run prompts you to sign in at console.anthropic.com)
# Verify
radioactive_ralph doctorIf you're not using a given provider, ignore its doctor warning rather than installing something you won't use.
Service-install errors
Symptom (macOS)
launchctl bootstrap failed: 5: Input/output error5: I/O error from launchctl usually means the generated definition is
syntactically valid but references a binary launchctl can't execute
(permissions or SIP).
Fix (macOS)
# 1. Verify the binary is executable
ls -l $(which radioactive_ralph)
# 2. Re-install
radioactive_ralph service uninstall
radioactive_ralph service installSymptom (Linux)
systemctl --user: Failed to connect to bus: No such file or directoryFix (Linux)
systemd --user requires a user session bus. Under SSH on a headless
box:
export XDG_RUNTIME_DIR=/run/user/$UID
loginctl enable-linger $USER # keep the user bus alive across sessionsThen re-run service install.
Symptom (native Windows)
service install failed: native Windows SCM service installation is disabledFix (native Windows)
Do not elevate and retry. For limited native control-plane inspection, run the supervisor in the foreground:
radioactive_ralph --supervisorNative provider worker startup still returns ErrPTYUnsupported; use WSL2 with
the Linux systemd --user service for functional execution. If
radioactive_ralph service status reports an SCM registration left by an
earlier development build, do not start it; remove it with
radioactive_ralph service uninstall. The
Windows SCM safety contract
explains the identity and ACL proof required before native service support can
return.
Worker stuck / no progress
Symptom
A task looks claimed but no evidence and no state transition for a long time, and the agent process is gone.
What it means
The watchdog's stall/no-output detection should have killed and reclaimed it already; if it hasn't, the reaper sweeps it on its next pass. This is expected transient behavior, not a hang — the never-block invariant means the system self-corrects rather than waiting.
Fix
Give the reaper a pass, then re-check. If the same step keeps failing to make progress across multiple reclaim cycles, that's a signal the step itself (or its acceptance criteria) needs attention, not the runtime.
When everything else fails
Capture state and open an issue:
radioactive_ralph doctor > /tmp/ralph-doctor.txt
radioactive_ralph --supervisor --log-format json 2> /tmp/ralph-supervisor.log &(Or the platform log equivalent — journalctl, macOS Console, Windows
Event Viewer.)
File at https://github.com/jbcom/radioactive-ralph/issues with those attached.